RE-2Y(St)H & RE-2X(St)H MP
RE-2Y(St)H & RE-2X(St)H MP

RE-2Y(St)H & RE-2X(St)H MP

Über dieses Produkt

WebsiteBesuchen Sie die Produktseite
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black cores numbered 1-2-3…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2
Ähnliche Produkte
1/15
RE-2Y(St)H & RE-2X(St)H-MP
RE-2Y(St)H & RE-2X(St)H-MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MUL...
DE-72175 Dornhan
RE-2Y(St)H&RE-2X(St)H-MP
RE-2Y(St)H&RE-2X(St)H-MP
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2...
DE-72175 Dornhan
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZ...
DE-72175 Dornhan
RE-2Y(St)Y-fl & RE-2X(St)Y-fl
RE-2Y(St)Y-fl & RE-2X(St)Y-fl
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl,SINGLE & MULTI-TRI...
DE-72175 Dornhan
RE-2Y(St)Y-fl & RE-2X(St)Y-fl MP
RE-2Y(St)Y-fl & RE-2X(St)Y-fl MP
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl,SINGLE & MULTI-PAIR,...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H
RE-2Y(St)H & RE-2X(St)H
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & M...
DE-72175 Dornhan
RE-2Y(St)HSWAH&RE-2X(St)HSWAH
RE-2Y(St)HSWAH&RE-2X(St)HSWAH
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATH...
DE-72175 Dornhan
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl
INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PVC INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of a...
DE-72175 Dornhan
RE-2Y(St)Y-fl
RE-2Y(St)Y-fl
INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for...
DE-72175 Dornhan
RE-2Y(St)Y & RE-2X(St)Y
RE-2Y(St)Y & RE-2X(St)Y
INSTRUMENTATION CONTROL CABLES, EN 50288-7RE-2Y(St)Y,ÇOK DAMARLI, PE YALITIMLI, GENEL EKRANLI, PVC KILIFLIRE-2X(St)Y,ÇOK DAMARLI, XLPE YALITIMLI, GENE...
DE-72175 Dornhan
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)...
DE-72175 Dornhan
RE-2Y(St)H-PIMF & RE-2X(St)H-PIMF
RE-2Y(St)H-PIMF & RE-2X(St)H-PIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H-PIM...
DE-72175 Dornhan
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)...
DE-72175 Dornhan
RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF
RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCR...
DE-72175 Dornhan
RE-2Y(St)YSWAY-fl-PIMF & RE-2X(St)YSWAY-fl-PIMF
RE-2Y(St)YSWAY-fl-PIMF & RE-2X(St)YSWAY-fl-PIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)YS...
DE-72175 Dornhan
Trend-Produkte
1/15
Bagger
Bagger
ÁRIK 21 - AGRO KFT
HU-9500 Celldömölk
AdBlue 1000 Liter IBC Container
AdBlue 1000 Liter IBC Container
Moser Handels GmbH
DE-86447 Todtenweis
Auto Hebebühne 2500kg 15cm flach
Auto Hebebühne 2500kg 15cm flach
fradashop GmbH
DE-49716 Meppen
HERMES SENDUNGSVERFOLGUNG
HERMES SENDUNGSVERFOLGUNG
Meine Sendungsverfolgung
DE-18439 Stralsund
Radlader
Radlader
WEMATIK GmbH
DE-48531 Nordhorn
Parfüm
Parfüm
Parfum Trend
DE-63517 Rodenbach
Wohncontainer
Wohncontainer
Craiss Metallmanufaktur GmbH
DE-75449 Wurmberg
Werkzeugfräsmaschine Deckel FP3-aktiv
Werkzeugfräsmaschine Deckel FP3-aktiv
Franz Singer Werkzeugmaschinen GmbH
DE-82538 Geretsried / Gelting
SunPower®-Module
SunPower®-Module
activ solar Schweiz GmbH
CH-8617 Mönchaltorf
Spanplatten
Spanplatten
Wemaflex GmbH Holzwerkstoffe
DE-33034 Brakel
Schiffsbau
Schiffsbau
Lakowa Gesellschaft für Kunststoffbe- und -verarbeitung mbH
DE-02681 Wilthen